Modular Veterinary Monitor HD-11

HD-11

Kewayon kulawa: HR, ECG, SPO2, NIBP, RESP, TEMP, CO2

Adana bayanai na sama da awanni 1200

Mainstream/bypass ETCO2 dubawa a matsayin ma'auni

 


Cikakken Bayani

Siga

1280*800 LCD nuni
Mainstream/bypass ETCO2 dubawa a matsayin ma'auni
Fiye da harsuna 5 na aikin sadarwa (na zaɓi)
nau'ikan 20 na ƙararrawar taron arrhythmia, goyan bayan aikin bincike na ɓangaren ST
Ayyukan bugawa mai tayar da hankali, ana yin rikodin kowane rashin daidaituwa cikin lokaci
Babban ƙarfin ginanniyar baturin lithium, ci gaba da aiki ≥ mintuna 300
Anti-defibrillation, wuka na lantarki, grid, tsangwama inotropic

Na'urorin haɗi:

Wayar zuciya mai guba biyar*1
Binciken yanayin zafin jiki*1
Binciken iskar oxygen na jini*1
Bututun tsawan hawan jini*1
Ciwon hawan jini*4 (ana iya zubarwa)
Zane-zanen lantarki *25 ko shirye-shiryen bidiyo*25

ECG:
Zaɓin jagora: daidaitattun jagora uku/biyar;Ana iya nunawa har zuwa jagora 7 akan allo ɗaya
Ⅰ, Ⅱ, Ⅲ, AVR, AVL, AVF, V kirjin kai
Kewayon gano ƙimar ECG: 15 ~ 350bpm
Resolution: 1bpm
Daidaiton ma'auni: ± 2% ko ± 2bpm na mafi girma
Amsar mitar: 0.67 Hz-40 Hz
ST sashi saka idanu: -2.0mV ~ 2.0mV
Alamar kashe Electrode: sauti, saurin haske
Gudun dubawa: 6.25, 12.5, 25, 50mm/sec
Zaɓin riba: ×0.125, ×0.25, ×0.5, ×1, ×2, ×4, atomatik
Ƙimar ECG: 1mV+5%
Keɓewar kariya ta jure wa ƙarfin lantarki na 4000V/AC/50Hz;
ECG na USB gubar waya: 3/5 gubar
Daidaitaccen daidaitawa: nau'in nau'in nau'in nau'in nau'in gubar na ECG na duniya
Zaɓi sanyi: kebul na USB na ECG takamaiman bincike, (kananan shirin al'ada)
Ƙararrawa: Ƙimar ƙararrawa babba da ƙananan iyaka za a iya saita, ƙwaƙwalwar atomatik;tare da sake dubawa na ƙararrawa

 

Oxygen saturation:
Nuni: Ƙimar oximetry, jadawali sandar bugun bugun jini, tsarin igiyar ruwa, ƙimar bugun jini
Oximetry kewayon: 0% -100% equine/canine/feline
Matsakaicin: 1%
Daidaito: ± 3% (ba a bayyana a ƙasa 70%)
Yawan bugun jini.
Ma'auni: 30 zuwa 280bpm
Daidaitaccen ƙimar bugun bugun jini: ± 2bpm
Ƙararrawa: 20 ~ 300bpm, ƙananan iyaka ba zai iya zama mafi girma fiye da babba ba
Daidaitaccen daidaitawa: nau'in clip na canine, nau'in shirin feline
Zaɓi tsari: nau'in budle
Ƙimar ƙararrawa: babba da ƙananan iyaka za a iya saita, ƙwaƙwalwar atomatik

 

Hawan jini mara lalacewa:
Hanyar aunawa: Hanyar oscillometric
Sifofin aunawa: hawan jini na systolic, hawan jini na diastolic, matsa lamba
Yanayin aiki: manual, atomatik, ci gaba da aunawa
Raka'a: mmHg/kPa na zaɓi
Lokacin ma'aunin ma'auni ta atomatik: 2.5 ~ 120min matakan daidaitawa
Kariyar wuce gona da iri: software da kariyar wuce gona da iri

Matsayin matsa lamba: 0-300 mmHg
Daidaitaccen tsari: 4-8, 6-11, 7-13, 8-15 cm
Zaɓi tsari: Babu
Kewayon saitin ƙararrawa.
Systolic matsa lamba: 40 ~ 255 mmHg, kuma ƙananan iyaka ba zai iya zama mafi girma fiye da babba iyaka (Marko),
40 ~ 200mmHg, kuma ƙananan iyaka ba zai iya zama mafi girma fiye da babba iyaka (Canidae), da
40 ~ 135mmHg, kuma ƙananan iyaka ba zai iya zama mafi girma fiye da babba (feline).
Diastolic hawan jini: 10 ~ 195mmHg, kuma ƙananan iyaka ba zai iya zama mafi girma fiye da babba iyaka (Equidae), da
10 ~ 150mmHg, kuma ƙananan iyaka ba zai iya zama mafi girma fiye da babba iyaka (Canidae), da
10 ~ 110mmHg da ƙananan iyaka ba zai iya zama mafi girma fiye da babba iyaka (feline).
Matsakaicin matsa lamba: 20 ~ 215mmHg, kuma ƙananan iyaka ba zai iya zama mafi girma fiye da babba iyaka (Equidae), da
20 ~ 165mmHg, kuma ƙananan iyaka ba zai iya zama mafi girma fiye da babba iyaka (Canidae), da
20 ~ 125mmHg, kuma ƙananan iyaka ba zai iya zama mafi girma fiye da babba iyaka (feline).
Kuskuren nunin ƙararrawa: bai fi ± 5% na ƙimar saita ba.

 

Yanayin jiki:
Ma'aunin zafin jiki: 15 ℃ ~ 50 ℃
Kuskuren auna zafin jiki: bai fi ± 0.1 ℃ ba
Ƙaddamarwa: 0.1 ℃
Daidaito: ± 0.2 ℃ (ciki har da kuskuren firikwensin)
Daidaitaccen daidaitawa: binciken yanayin zafin jiki na dindindin
Zaɓi sanyi: binciken zafin jiki na esophageal, binciken zafin jiki na dubura
Ƙimar ƙararrawa: babba da ƙananan iyaka za a iya saita, ƙwaƙwalwar atomatik
Ƙararrawa: Ana iya saita saitunan ƙararrawa don duk sigogin saka idanu, kuma yana da na'urar ƙararrawa wanda ke fitar da sauti da haske, kuma yana iya soke ƙararrawa.

 

Numfashi:
Hanyar aunawa: Hanyar thoracic impedance
Kewayon ƙimar ƙimar numfashi da daidaito
Kewayon aunawa: Equidae: 0 ~ 120rpm.
Canine / Feline: 0 ~ 150rpm.
Daidaitaccen ma'auni: 10 ~ 150 rpm ± 2 rpm ko ± 2%, duk wanda ya fi girma.0 ~ 9 rpm ba a bayyana ba.
Ƙimar auna yawan numfashi
Resolution: 1 rpm
Lokacin jinkirin ƙararrawar asphyxia
Ana iya saita shi azaman: 20s, 25s, 30s, 35s, 40s, 45s, 50s, 55s, 60s
Iyakar ƙararrawar ƙimar numfashi
Ana iya saita iyakar ƙararrawa daga 2 zuwa 150rpm

 

 

Samfura masu dangantaka