Tsarin Kula da Marasa lafiya na Dabbobi HD10

HD-10


Cikakken Bayani

Farashin ECG

Module na numfashi

Hawan jini

Module na Oximetry

Yanayin jiki

Carbon dioxide

Daidaitaccen daidaitawa: ECG, oxygen na jini, hawan jini, ƙimar numfashi, zafin jiki, ƙimar zuciya.
Tsarin zaɓi na zaɓi: allon capacitive, firinta, WIFI, al'ada / kewaye ETCO2, Masimo oxygen jini, Suntech hawan jini, da dai sauransu.
Na'urorin haɗi: waya mai gubar gubar guda biyar * 1, binciken oxygen na jini * 1, bututun tsawan hawan jini * 1, cuff mai karfin jini * 4, takardar lantarki mai zubarwa * 15, igiyar wuta * 1.
Na'urorin haɗi na zaɓi: dollies, bangon bango, da sauransu.

Linux tsarin aiki, dangane da Multi-mai amfani, Multi-tasking, Multi-CPU tsarin aiki;kyakkyawar mu'amala mai mu'amala da aminci da kwanciyar hankali na aiki;HD10VETdabba dubasanye take da tsarin aiki na Linux don cimma haɓaka fasahar yanki da yawa;Haɗin WIFI zuwa tashar sa ido ta tsakiya, da haɓaka USB, faɗaɗa TV da sauran manyan saka idanu na allo (na zaɓi), da sauransu.

Hanyar nuni da jagora bakwai allo iri ɗaya.
Kewayon ma'aunin bugun zuciya: 20-350bpm.
Ƙararrawa: 20-350bpm.
Matsakaicin ƙin yarda da yanayin gama gari ≥105db.
Gudun waveform 6.25, 12.5, 25, 50mm/s matakan zaɓi huɗu.
Samun zaɓi Yanayin zaɓi bakwai.
Ƙarar QRS tare da matakan daidaitawa 5.
Yanayin Kulawa Bincike, saka idanu, tiyata, ST hanyoyin sa ido hudu.
Binciken bugun zuciya arrhythmia Tare da nau'ikan bincike iri 23 na ƙididdigar bugun zuciya.
Kariyar Electrodebrider Module na ECG na iya aiki akai-akai a cikin yanayin tsangwama na lantarki tare da yankan wutar lantarki na 300W da ƙarfin coagulation na 100W, kuma daidaito ba ya shafar.

Ma'auni: 0 - 150 numfashi / min.
Hankalin tashin hankali na numfashi na siginar Sine, 62.8kHz (± 10%), <500μA.
Ƙararrawar asphyxiation tare da fiye da matakan 9 na saitin ƙayyadaddun lokacin ƙararrawa.
Samun daidaitawa tare da matakan 8 na daidaitawar riba.

Ma'auni kewayon hawan jini (raka'a) Equine Canine Feline
Systolic hawan jini mmHg 40-255 40-200 40-135
kPa 5.3-34.0 5.3-26.7 5.3-18.0
Diastolic hawan jini mmHg 20-205 20-150 20-100
kPa 2.7-27.3 2.7-20.0 2.7-13.3
Matsakaicin matsa lamba mmHg 27-220 27-165 27-110
kPa 3.6-29.3 3.6-22.0 3.6-14.7
Matsakaicin ma'aunin ma'auni: 0 ~ 290± 3mmHg.
Kariyar wuce gona da iri na software Equine: bai wuce 293 mmHg ba
Canidae: ba fiye da 250 mmHg ba.
Feline: kada ya wuce 148 mmHg.
Kariyar overpressure Hardware Equidae/canines: har zuwa 300 mmHg.
Feline: har zuwa 150 mmHg.
Tazarar ma'auni a cikin yanayin atomatik 2.5 min, 5 min, 10 min, 15 min, 20 min, 30 min, 45 min, 60 min, 90 min, 120 min.

 

Ma'auni: 69% -100%.
Sautin bugun jini Tare da aikin sauya sautin bugun jini.
Gudun waveform 3 ko fiye da zaɓuɓɓukan saurin igiyar ruwa.
Hankali 3 zaɓuɓɓukan hankali akwai.

HD10Vet dabba mai saka idanu yana ɗaukar tsarin tsarin yanayin zafin jiki biyu, tare da nunin bambancin zafin tashoshi biyu.
nuni na ainihin-lokaci na cikakkiyar ƙimar bambancin zafin jiki da aka auna.

Ma'auni: 0mmHg-114mmHg
Ayyukan ramuwa tare da O2, diyya ta atomatik don matsa lamba na yanayi, N2O diyya
Ayyukan aunawa: FiCO2, EtCO2, awRR