Veterinary Modular Saib HD-11

HD-11

Saib xyuas ntau yam: HR, ECG, SPO2, NIBP, RESP, TEMP, CO2

Cov ntaub ntawv khaws cia ntau tshaj 1200 teev

Mainstream / bypass ETCO2 interface raws li tus qauv

 


Product Detail

Tsis muaj

1280 * 800 LCD zaub
Mainstream / bypass ETCO2 interface raws li tus qauv
Ntau tshaj 5 hom lus ua haujlwm interface (yeem)
20 hom arrhythmia xwm txheej tswb, txhawb ST ntu tsom xam muaj nuj nqi
Ua kom muaj nuj nqi luam ntawv, txhua qhov txawv txav tau sau tseg hauv lub sijhawm
Lub peev xwm loj built-in lithium roj teeb, lub sijhawm ua haujlwm tsis tu ncua ≥ 300 feeb
Anti-defibrillation, hluav taws xob riam, kab sib chaws, inotropic cuam tshuam

Accessories:

Tsib lub plawv hlau * 1
Lub cev kub sojntsuam * 1
Ntshav oxygen soj ntsuam * 1
Ntshav siab Extension tube * 1
Ntshav siab cuff * 4 (tso pov tseg)
Cov ntawv pov tseg electrode * 25 lossis clips * 25

ECG:
Lead xaiv: peb-/ tsib-tus qauv;mus txog 7 leads tuaj yeem tso tawm ntawm tib lub vijtsam
Ⅰ, Ⅱ, Ⅲ, AVR, AVL, AVF, V hauv siab
ECG tus nqi ntsuas ntau: 15 ~ 350bpm
Kev daws teeb meem: 1bpm
Kev ntsuas qhov tseeb: ± 2% lossis ± 2bpm ntawm qhov ntau dua
Zaus teb: 0.67 Hz-40 Hz
ST ntu saib xyuas: -2.0mV ~ 2.0mV
Electrode tawm qhov taw qhia: suab, lub teeb tam sim
Scan ceev: 6.25, 12.5, 25, 50mm / sec
Kev xaiv tau: × 0.125, × 0.25, × 0.5, × 1, × 2, × 4, tsis siv neeg
Kev ntsuas ECG: 1mV + 5%
Kev tiv thaiv kev sib cais tiv taus 4000V / AC / 50Hz voltage;
ECG cable lead hlau: 3/5 lead
Txheem configuration: tsib-lead buckle hom universal ECG cable
Xaiv kev teeb tsa: kev tshawb fawb tshwj xeeb ECG cable cable, (kev cai me me clip)
Tswb: ceeb toom tus nqi sab sauv thiab qis qis tuaj yeem teeb tsa, tsis siv neeg nco;nrog lub tswb ntsuas

 

Oxygen saturation:
Zaub: Oximetry tus nqi, mem tes bar graph, waveform, mem tes tus nqi
Oximetry ntau yam: 0% -100% equine / canine / feline
Kev daws teeb meem: 1%
Qhov tseeb: ± 3% (tsis txhais tau qis dua 70%)
Pulse tus nqi.
Kev ntsuas ntau: 30 txog 280bpm
Pulse tus nqi: ± 2bpm
Tswb ntau: 20 ~ 300bpm, qhov qis qis tsis tuaj yeem siab tshaj qhov txwv sab saud
Standard configuration: canine clip hom, feline clip hom
Xaiv configuration: bundle type
Tswb tus nqi: sab sauv thiab qis qis tuaj yeem teeb tsa, tsis siv neeg nco

 

Tsis-invasive ntshav siab:
Txoj kev ntsuas: oscillometric method
Kev ntsuas ntsuas: systolic ntshav siab, diastolic ntshav siab, txhais tau tias siab
Ua hauj lwm hom: phau ntawv, tsis siv neeg, nruam ntsuas
Chav nyob: mmHg/kPa yeem
Tsis siv neeg ntsuas hom ntsuas lub sijhawm ncua sijhawm: 2.5 ~ 120min kaum qib kho tau
Kev tiv thaiv overpressure: software thiab hardware overpressure tiv thaiv

Cuff siab ntau: 0-300 mmHg
Standard configuration: 4-8, 6-11, 7-13, 8-15 cm
Xaiv configuration: Tsis muaj
Tswb teem ntau yam.
Systolic siab: 40 ~ 255 mmHg, thiab qhov qis qis tsis tuaj yeem siab tshaj qhov txwv siab (Marko),
40 ~ 200mmHg, thiab qhov qis qis tsis tuaj yeem siab tshaj qhov txwv siab (Canidae), thiab
40 ~ 135mmHg, thiab qhov txwv qis tsis tuaj yeem siab tshaj qhov txwv sab sauv (feline).
Diastolic ntshav siab: 10 ~ 195mmHg, thiab qhov qis qis tsis tuaj yeem siab tshaj qhov txwv siab (Equidae), thiab
10 ~ 150mmHg, thiab qhov qis qis tsis tuaj yeem siab tshaj qhov txwv siab (Canidae), thiab
10 ~ 110mmHg thiab qhov txwv qis tsis tuaj yeem siab tshaj qhov txwv sab sauv (feline).
Lub ntsiab lus siab: 20 ~ 215mmHg, thiab qhov qis qis tsis tuaj yeem siab tshaj qhov txwv siab (Equidae), thiab
20 ~ 165mmHg, thiab qhov qis qis tsis tuaj yeem siab tshaj qhov txwv siab (Canidae), thiab
20 ~ 125mmHg, thiab qhov txwv qis tsis tuaj yeem siab tshaj qhov txwv sab sauv (feline).
Tswb tso saib yuam kev: tsis ntau tshaj ± 5% ntawm tus nqi teev.

 

Lub cev kub:
Lub cev kub ntsuas ntau yam: 15 ℃ ~ 50 ℃
Lub cev kub ntsuas qhov yuam kev: tsis ntau tshaj ± 0.1 ℃
Kev daws teeb meem: 0.1 ℃
Qhov tseeb: ± 0.2 ℃ (nrog rau qhov yuam kev ntawm lub sensor)
Standard configuration: lub cev nto mus tas li lub cev kub soj ntsuam
Xaiv configuration: esophageal lub cev kub sojntsuam, qhov quav lub cev kub sojntsuam
Tswb tus nqi: sab sauv thiab qis qis tuaj yeem teeb tsa, tsis siv neeg nco
Tswb: Lub tswb ceeb toom tuaj yeem teeb tsa rau txhua qhov ntsuas ntsuas, thiab muaj lub tswb nrov uas tawm suab thiab lub teeb, thiab tuaj yeem tshem lub tswb

 

Ua pa:
Txoj kev ntsuas: txoj kev thoracic impedance
Kev ntsuas pa ntsuas ntau thiab qhov tseeb
Kev ntsuas ntau: Equidae: 0 ~ 120rpm.
Canine / Feline: 0 ~ 150rpm.
Kev ntsuas qhov tseeb: 10 ~ 150 rpm ± 2 rpm lossis ± 2%, qhov twg ntau dua.0 ~ 9 rpm tsis tau txhais.
Kev ntsuas ntsuas qhov ntsuas pa
Kev daws teeb meem: 1 rpm
Asphyxia tswb ncua sij hawm
Muaj peev xwm muab tau raws li: 20s, 25s, 30s, 35s, 40s, 45s, 50s, 55s, 60s
Respiration rate tswb limit range
Tswb txwv yuav teem tau los ntawm 2 mus rau 150 rpm