1280 * 800 LCD kuratidza
Mainstream/bypass ETCO2 interface seyakajairwa
Inopfuura mitauro mishanu yekushandisa interface (inosarudza)
20 marudzi earrhythmia chiitiko alarm, tsigira ST chikamu chekuongorora basa
Trigger kudhinda basa, imwe neimwe isiriyo inonyorwa nenguva
Huru huwandu hwakavakirwa-mukati lithium bhatiri, inoenderera yekushanda nguva ≥ 300 maminetsi
Anti-defibrillation, banga remagetsi, grid, inotropic kupindira
Zvishandiso:
Waya yemoyo inotungamira mashanu*1
Kuongorora tembiricha yepamusoro pemuviri *1
Ropa okisijeni probe*1
Kuwedzerwa kweropa rekuwedzera chubhu*1
Kumanikidzwa kweropa cuff * 4 (inoraswa)
Disposable electrode sheets * 25 kana zvimedu * 25
ECG:
Kutungamira kusarudzwa: zvitatu-/zvishanu-kutungamira chiyero;anosvika manomwe anotungamira anogona kuratidzwa pane imwechete skrini
Ⅰ, Ⅱ, Ⅲ, AVR, AVL, AVF, V anotungamira pachipfuva
ECG kukosha kwekuona huwandu: 15 ~ 350bpm
Chisarudzo: 1bpm
Kuyera kwechiyero: ± 2% kana ± 2bpm yehukuru
Frequency mhinduro: 0.67 Hz-40 Hz
ST chikamu chekutarisa: -2.0mV ~ 2.0mV
Electrode off chiratidzo: ruzha, chiedza chekukurumidza
Scan kumhanya: 6.25, 12.5, 25, 50mm/sec
Kuwana sarudzo: × 0.125, × 0.25, × 0.5, × 1, × 2, × 4, otomatiki
ECG calibration: 1mV + 5%
Dziviriro yekuzviparadzanisa inomira 4000V / AC / 50Hz voltage;
ECG tambo inotungamira waya: 3/5 inotungamira
Kugadziriswa kwakajairwa: mashanu-lead buckle mhando yepasirese ECG tambo
Sarudza gadziriro: tsvakiridzo-chaiyo ECG tambo tambo, (tsika diki clip)
Alarm: kukosha kwearamu yepamusoro uye yakaderera miganho inogona kusetwa, otomatiki ndangariro;ne alarm wongororo
Oxygen saturation:
Ratidza: Oximetry kukosha, pulse bar graph, waveform, pulse value
Oximetry range: 0% -100% equine / canine / feline
Chisarudzo: 1%
Kururama: ± 3% (isina kutsanangurwa pazasi 70%)
Pulse rate.
Chiyero chiyero: 30 kusvika 280bpm
Pulse rate kunyatsoita: ± 2bpm
Alarm range: 20 ~ 300bpm, muganho wepasi haugone kuve wakakura kupfuura wepamusoro muganho
Kugadziriswa kwakajairwa: canine clip type, feline clip type
Sarudza gadziriso: bundle type
Alarm kukosha: yepamusoro uye yakaderera miganho inogona kusetwa, otomatiki ndangariro
Non-invasive blood pressure:
Kuyera nzira: oscillometric nzira
Zviyero zvipimo: systolic blood pressure, diastolic blood pressure, zvinoreva kumanikidzwa
Kushanda mode: manual, otomatiki, inoenderera kuyerwa
Mayuniti: mmHg/kPa sarudzo
Otomatiki kuyerwa muoti kuyera nguva yenguva: 2.5 ~ 120min gumi mazinga anochinjika
Kudzivirirwa kwepamusoro: software uye hardware overpressure kudzivirira
Cuff pressure range: 0-300 mmHg
Kugadziriswa kwakajairwa: 4-8, 6-11, 7-13, 8-15 cm
Sarudza gadziriso: Hapana
Alarm setting range.
Systolic pressure: 40 ~ 255 mmHg, uye muganho wakaderera haugone kuva mukuru pane wepamusoro muganho (Marko), iyo
40 ~ 200mmHg, uye muganho wepasi haugone kuva mukuru pane wepamusoro muganho (Canidae), uye
40 ~ 135mmHg, uye muganho wepasi haugone kuva mukuru pane wepamusoro muganhu (feline).
Diastolic blood pressure: 10 ~ 195mmHg, uye muganho wakaderera haugone kuva mukuru pane wepamusoro muganho (Equidae), uye
10 ~ 150mmHg, uye muganho wepasi haugone kuva mukuru pane wepamusoro muganho (Canidae), uye
10 ~ 110mmHg uye muganho wepasi haugone kuva mukuru pane wepamusoro muganho (feline).
Zvinoreva kumanikidza: 20 ~ 215mmHg, uye muganho wepasi haugone kuve wakakura kupfuura wepamusoro muganho (Equidae), uye
20 ~ 165mmHg, uye muganho wepasi haugone kuva mukuru pane wepamusoro muganho (Canidae), uye
20 ~ 125mmHg, uye muganho wepasi haugone kuva mukuru pane wepamusoro muganhu (feline).
Alarm kuratidza kukanganisa: hapana yakakura kupfuura ± 5% yemutengo wakaiswa.
Tembiricha yemuviri:
Kuyera kwekushisa kwemuviri kuyerwa: 15℃~50℃
Chikanganiso chekuyera kupisa kwemuviri: hapana chikuru kupfuura ± 0.1 ℃
Kugadzirisa: 0.1 ℃
Kurongeka: ± 0.2 ℃ (kusanganisira kukanganisa kwe sensor)
Standard configuration: body surface isingaperi tembiricha yemuviri probe
Sarudza kugadzirisa: esophageal tembiricha yemuviri probe, rectal tembiricha yemuviri probe
Alarm kukosha: yepamusoro uye yakaderera miganho inogona kusetwa, otomatiki ndangariro
Alarm: zvigadziriso zvealarm zvinogona kusetwa kune ese ekutarisa ma paramita, uye ine alarm mudziyo unoburitsa ruzha uye chiedza, uye unogona kudzima alarm.
Kufema:
Chiyero nzira: thoracic impedance nzira
Kufema mwero kuyerwa chiyero uye nemazvo
Chiyero chiyero: Equidae: 0 ~ 120rpm.
Canine / Feline: 0 ~ 150rpm.
Kuyera kwechiyero: 10 ~ 150 rpm ± 2 rpm kana ± 2%, chero ipi zvayo yakakura.0 ~ 9 rpm haina kutsanangurwa.
Kugadziriswa kwechiyero chekufema
Kugadzirisa: 1 rpm
Asphyxia alarm kunonoka nguva
Inogona kuiswa se: 20s, 25s, 30s, 35s, 40s, 45s, 50s, 55s, 60s
Kufemerwa kwearamu kuganhura range
Alarm muganho anogona kusetwa kubva 2 kusvika 150rpm