Veterinary Patient Monitoring Systems HD10

HD-10


Product Detail

ECG module

Kufema Module

Blood Pressure

Oximetry Module

Kupisa kwemuviri

Carbon dioxide

Kugadziriswa kwakajairwa: ECG, okisijeni yeropa, BP, kufema, tembiricha, kurova kwemoyo.
Optional configuration: capacitive screen, printer, WIFI, mainstream/bypass ETCO2, Masimo ropa okisijeni, Suntech blood pressure, etc.
Zvishandiso: shanu-lead heart waya * 1, blood oxygen probe * 1, blood pressure yekuwedzera chubhu * 1, blood pressure cuff * 4, disposable electrode sheet * 15, tambo yemagetsi * 1.
Optional accessories: madhoiri, mabhureki emadziro, nezvimwe.

Linux inoshanda sisitimu, yakavakirwa pane akawanda-mushandisi, akawanda-tasking, akawanda-CPU anoshanda system;yakanaka interactive interface pamwe nekuchengetedza uye kugadzikana kushanda kuyerera;HD10VETmhuka monitoryakashongedzerwa neLinux inoshanda sisitimu yekuwana yakawanda-domain tekinoroji yekuwedzera;WIFI yekubatanidza kune yepakati yekutarisisa chiteshi, pamwe ne USB kukwidziridzwa, kuwedzera kweTV uye imwe yakakura skrini yekutarisa (sarudzo), nezvimwe.

Ratidza nzira yechinomwe-lead chidzitiro chimwe chete.
Kuyera kwemoyo kuyerwa: 20-350bpm.
Alarm range: 20-350bpm.
Common mode kurambwa reshiyo ≥105db.
Waveform kumhanya 6.25, 12.5, 25, 50mm/s mana mazinga ekusarudza.
Wana sarudzo Manomwe ekusarudza modhi.
QRS vhoriyamu ine 5 mazinga ekugadzirisa.
Monitoring mode Kuongorora, kutarisa, kuvhiyiwa, ST mana ekutarisa maitiro.
Kuongorora kwemoyo arrhythmia Nemhando makumi maviri nenhatu dzekurova kwemoyo arrhythmia.
Electrodebrider kuchengetedza Iyo ECG module inogona kushanda zvakajairika munzvimbo ye electrosurgical interference ine electrodebrider yekucheka simba re300W uye coagulation simba re100W, uye iko kurongeka hakukanganisi.

Chiyero chekuyera: 0 - 150 kufema / min.
Kufemerwa kuwedzeredza waveform Sine wave chiratidzo, 62.8kHz (±10%), <500μA.
Asphyxiation alarm ine anopfuura 9 mazinga earamu nguva yekumisikidza.
Wana kugadzirisa ne8 mazinga ekugadzirisa kugadzirisa.

Chiyero chekuyeresa Shinikidzo yeropa (mayuniti) Equine Canine Feline
Systolic blood pressure mmHg 40-255 40-200 40-135
kPa 5.3-34.0 5.3-26.7 5.3-18.0
Diastolic blood pressure mmHg 20-205 20-150 20-100
kPa 2.7-27.3 2.7-20.0 2.7-13.3
Zvinoreva kumanikidzwa mmHg 27-220 27-165 27-110
kPa 3.6-29.3 3.6-22.0 3.6-14.7
Cuff kudzvinyirirwa kuyerwa chiyero: 0 ~ 290±3mmHg.
Software overpressure dziviriro Equine: hapana kupfuura 293 mmHg
Canidae: kwete kupfuura 250 mmHg.
Feline: haifaniri kudarika 148 mmHg.
Hardware overpressure kudzivirira Equidae/canines: kusvika ku300 mmHg.
Feline: kusvika ku150 mmHg.
Kuyera kupindirana mune otomatiki modhi 2.5 min, 5 min, 10 min, 15 min, 20 min, 30 min, 45 min, 60 min, 90 min, 120 min.

 

Chiyero chekuyera: 69% -100%.
Pulse Tone Ne pulse toni switch function.
Waveform kumhanya 3 kana kupfuura waveform kumhanya sarudzo.
Sensitivity 3 sarudzo dzekunzwa dziripo.

HD10Vet mhuka yekutarisa inotora maviri maviri emuviri tembiricha module kumisikidzwa, ine mbiri-chiteshi tembiricha musiyano wekuratidzira.
chaiyo-nguva kuratidzwa kweiyo asolute kukosha kweyero yetembiricha musiyano.

Chiyero chiyero: 0mmHg-114mmHg
Muripo wekuita neO2, otomatiki muripo wekumanikidzwa kwemhepo, N2O muripo
Chiyero basa: FiCO2, EtCO2, awRR