I-Veterinary Modular Monitor HD-11

I-HD-11

Ibanga lokuqapha: HR, ECG, SPO2, NIBP, RESP, TEMP, CO2

Ukugcinwa kwedatha okungaphezu kwamahora angu-1200

I-Mainstream/bypass interface ye-ETCO2 njengejwayelekile

 


Imininingwane Yomkhiqizo

Amapharamitha

1280*800 LCD isibonisi
I-Mainstream/bypass interface ye-ETCO2 njengejwayelekile
Ngaphezulu kwezilimi ezi-5 zokusebenzelana (kuyakhetheka)
Izinhlobo ezingama-20 ze-alamu yomcimbi we-arrhythmia, isekela umsebenzi wokuhlaziya ingxenye ye-ST
Qalisa umsebenzi wokuphrinta, ukungajwayelekile ngakunye kuqoshwa ngesikhathi
Umthamo omkhulu webhethri ye-lithium eyakhelwe ngaphakathi, isikhathi sokusebenza esiqhubekayo ≥ imizuzu engama-300
I-Anti-defibrillation, ummese kagesi, igridi, ukuphazamiseka kwe-inotropic

Izinsiza:

Intambo yenhliziyo yomthofu emihlanu*1
I-probe yezinga lokushisa lomzimba*1
I-blood oxygen probe*1
Ishubhu yokwandisa umfutho wegazi*1
Ikhafu yomfutho wegazi*4 (iyalahlwa)
Amashidi e-electrode alahlwayo*25 noma iziqeshana*25

I-ECG:
Ukukhetha okuholayo: izinga lokuhola okuthathu/okuhlanu;kufika ku-7 imikhondo ingaboniswa esikrinini esifanayo
Ⅰ, Ⅱ, Ⅲ, AVR, AVL, AVF, V imikhondo yesifuba
Ibanga lokutholwa kwenani le-ECG: 15~350bpm
Ukulungiswa: 1bpm
Ukunemba kokulinganisa: ±2% noma ±2bpm kokukhulu
Impendulo yemvamisa: 0.67 Hz-40 Hz
Ukuqapha kwengxenye ye-ST: -2.0mV~2.0mV
I-Electrode off inkomba: umsindo, ukukhanya
Isivinini sokuskena: 6.25, 12.5, 25, 50mm/sec
Ukukhethwa kokuthola: ×0.125, ×0.25, ×0.5, ×1, ×2, ×4, okuzenzakalelayo
Ukulinganiswa kwe-ECG: 1mV+5%
Ukuhlukaniswa kokuvikela ukumelana ne-voltage engu-4000V/AC/50Hz;
Intambo eholayo yekhebula ye-ECG: 3/5 lead
Ukucushwa okujwayelekile: uhlobo lwekhebuli ye-ECG enentambo yokuhola emihlanu
Khetha ukumisa: ikhebula lekhebula le-ECG eliqondene nocwaningo, (isiqeshana esincane sangokwezifiso)
I-alamu: inani le-alamu lingasethwa, inkumbulo ezenzakalelayo;ngokubuyekezwa kwe-alamu

 

Ukugcwala komoyampilo:
Bonisa: Inani le-Oximetry, igrafu yebha yokushaya, i-waveform, inani lokushaya kwenhliziyo
Ibanga le-Oximetry: 0% -100% i-equine/canine/feline
Isixazululo: 1%
Ukunemba: ±3% (akuchazwanga ngaphansi kuka-70%)
Izinga lokushaya kwenhliziyo.
Ibanga lokulinganisa: 30 kuya ku-280bpm
Ukunemba kwesilinganiso sokushaya kwenhliziyo: ±2bpm
Ibanga le-alamu: 20 ~ 300bpm, umkhawulo ophansi awukwazi ukuba mkhulu kunomkhawulo ophezulu
Ukucushwa okujwayelekile: uhlobo lwesiqeshana se-canine, uhlobo lwesiqeshana se-feline
Khetha ukumisa: uhlobo lwenqwaba
Inani le-alamu: imikhawulo ephezulu naphansi ingasethwa, inkumbulo ezenzakalelayo

 

I-non-invasive blood pressure:
Indlela yokulinganisa: indlela ye-oscillometric
Izilinganiso zokulinganisa: umfutho wegazi we-systolic, umfutho wegazi we-diastolic, umfutho wegazi
Imodi yokusebenza: ukulinganisa okwenziwa ngesandla, okuzenzakalelayo, okuqhubekayo
Amayunithi: mmHg/kPa ngokuzithandela
Isikhathi sokulinganisa semodi yokulinganisa ezenzakalelayo: 2.5 ~ 120min amazinga ayishumi alungisekayo
Ukuvikelwa kokucindezela ngokweqile: isoftware kanye nokuvikelwa kokucindezela kwehadiwe ngokweqile

Ibanga lokucindezela kwe-Cuff: 0-300 mmHg
Ukucushwa okujwayelekile: 4-8, 6-11, 7-13, 8-15 cm
Khetha ukumisa: Akukho
Ibanga lokusetha i-alamu.
Ingcindezi ye-Systolic: 40~255 mmHg, futhi umkhawulo ophansi awukwazi ukuba mkhulu kunomkhawulo ophezulu (Marko),
40 ~ 200mmHg, futhi umkhawulo ophansi awukwazi ukuba mkhulu kunomkhawulo ophezulu (Canidae), futhi
40~135mmHg, futhi umkhawulo ophansi awukwazi ukuba mkhulu kunomkhawulo ongaphezulu (inkabi).
Umfutho wegazi we-Diastolic: 10 ~ 195mmHg, futhi umkhawulo ophansi awukwazi ukuba mkhulu kunomkhawulo ophezulu (Equidae), futhi
10~150mmHg, futhi umkhawulo ophansi awukwazi ukuba mkhulu kunomkhawulo ongaphezulu (Canidae), futhi
10~110mmHg futhi umkhawulo ophansi awukwazi ukuba mkhulu kunomkhawulo ongaphezulu (inkabi).
Ingcindezi emaphakathi: 20~215mmHg, futhi umkhawulo ophansi awukwazi ukuba mkhulu kunomkhawulo ophezulu (Equidae), futhi
20~165mmHg, futhi umkhawulo ophansi awukwazi ukuba mkhulu kunomkhawulo ongaphezulu (Canidae), futhi
20~125mmHg, futhi umkhawulo ophansi awukwazi ukuba mkhulu kunomkhawulo ongaphezulu (inkabi).
Iphutha lokubonisa i-alamu: alikho ngaphezu kuka-±5% yenani elimisiwe.

 

Izinga lokushisa lomzimba:
Ibanga lokulinganisa izinga lokushisa lomzimba: 15℃~50℃
Iphutha lokulinganisa izinga lokushisa lomzimba: alikho ngaphezu kuka-±0.1℃
Ukulungiswa: 0.1℃
Ukunemba: ± 0.2 ℃ (kuhlanganise nephutha lenzwa)
Ukucushwa okujwayelekile: indawo yomzimba ehlala unomphela izinga lokushisa lomzimba
Khetha ukumisa: i-probe yezinga lokushisa lomzimba lomphimbo, i-rectal lokushisa lomzimba
Inani le-alamu: imikhawulo ephezulu naphansi ingasethwa, inkumbulo ezenzakalelayo
I-alamu: izilungiselelo ze-alamu zingasethwa kuwo wonke amapharamitha okuqapha, futhi inedivayisi ye-alamu ekhipha umsindo nokukhanya, futhi ingakhansela i-alamu.

 

Ukuphefumula:
Indlela yokulinganisa: indlela ye-thoracic impedance
Ibanga lokulinganisa izinga lokuphefumula nokunemba
Ibanga lokulinganisa: Equidae: 0 ~ 120rpm.
I-Canine / Feline: 0 ~ 150rpm.
Ukunemba kokulinganisa: 10~150 rpm ±2 rpm noma ±2%, noma yikuphi okukhulu.0~9 rpm akuchazwanga.
Ukulungiswa kokulinganisa izinga lokuphefumula
Ukulungiswa: 1 rpm
Isikhathi sokulibaziseka kwe-alamu ye-Asphyxia
Ingasethwa ngokuthi: 20s, 25s, 30s, 35s, 40s, 45s, 50s, 55s, 60s
Ibanga lomkhawulo we-alamu yezinga lokuphefumula
Umkhawulo we-alamu ungasethwa kusuka ku-2 kuye ku-150rpm