1280*800 LCD display
Mainstream/bypass ETCO2 interface as standard
More than 5 languages operation interface (optional)
20 kinds of arrhythmia event alarm, support ST segment analysis function
Trigger printing function, each abnormality is recorded in time
Large capacity built-in lithium battery, continuous working time ≥ 300 minutes
Anti-defibrillation, electric knife, grid, inotropic interference
HD11 veterinary monitor is mainly used for all kinds of small, medium and large-sized animals, pet surgery process monitoring, testing items are: blood oxygen, blood pressure, body temperature, electrocardiography, respiratory rate, heart rate, CO2, IBP and so on;
HD11 Vet animal monitor is a device or system to measure and prompt animal physiological parameters, and can be compared with the known set values, if there is not within the set value can be issued an alarm; is the animal body characteristics of the multi-faceted monitoring and early warning;
Standard with mainstream/bypass ETCO2 interface, support plug-and-play; avoid returning to the factory to upgrade the tedious communication;
Five-lead heart wire*1
Body surface temperature probe*1
Blood oxygen probe*1
Blood pressure extension tube*1
Blood pressure cuff*4 (disposable)
Disposable electrode sheets*25 or clips*25
ECG:
Lead selection: three-/five-lead standard; up to 7 leads can be displayed on the same screen
Ⅰ, Ⅱ, Ⅲ, AVR, AVL, AVF, V chest leads
ECG value detection range: 15~350bpm
Resolution: 1bpm
Measurement accuracy: ±2% or ±2bpm of the greater
Frequency response: 0.67 Hz-40 Hz
S-T segment monitoring: -2.0mV~2.0mV
Electrode off indication: sound, light prompt
Scan speed: 6.25, 12.5, 25, 50mm/sec
Gain selection: ×0.125, ×0.25, ×0.5, ×1, ×2, ×4, automatic
ECG calibration: 1mV+5%
Protection isolation withstand 4000V/AC/50Hz voltage;
ECG cable lead wire: 3/5 lead
Standard configuration: five-lead buckle type universal ECG cable
Select configuration: research-specific ECG cable cable, (custom small clip)
Alarm: alarm value upper and lower limits can be set, automatic memory; with alarm review
Oxygen saturation:
Display: Oximetry value, pulse bar graph, waveform, pulse value
Oximetry range: 0%-100% equine/canine/feline
Resolution: 1%
Accuracy: ±3% (not defined below 70%)
Pulse rate.
Measurement range: 30 to 280bpm
Pulse rate accuracy: ±2bpm
Alarm range: 20 ~ 300bpm, the lower limit can not be greater than the upper limit
Standard configuration: canine clip type, feline clip type
Select configuration: bundle type
Alarm value: upper and lower limits can be set, automatic memory
Non-invasive blood pressure:
Measurement method: oscillometric method
Measurement parameters: systolic blood pressure, diastolic blood pressure, mean pressure
Working mode: manual, automatic, continuous measurement
Units: mmHg/kPa optional
Automatic measurement mode measurement interval time: 2.5 ~ 120min ten levels adjustable
Overpressure protection: software and hardware overpressure protection
Cuff pressure range: 0-300 mmHg
Standard configuration: 4-8, 6-11, 7-13, 8-15 cm
Select configuration: None
Alarm setting range.
Systolic pressure: 40~255 mmHg, and the lower limit cannot be greater than the upper limit (Marko), the
40~200mmHg, and the lower limit cannot be greater than the upper limit (Canidae), and
40~135mmHg, and the lower limit cannot be greater than the upper limit (feline).
Diastolic blood pressure: 10~195mmHg, and the lower limit cannot be greater than the upper limit (Equidae), and
10~150mmHg, and the lower limit cannot be greater than the upper limit (Canidae), and
10~110mmHg and the lower limit cannot be greater than the upper limit (feline).
Mean pressure: 20~215mmHg, and the lower limit cannot be greater than the upper limit (Equidae), and
20~165mmHg, and the lower limit cannot be greater than the upper limit (Canidae), and
20~125mmHg, and the lower limit cannot be greater than the upper limit (feline).
Alarm display error: no greater than ±5% of the set value.
Body temperature:
Body temperature measurement range: 15℃~50℃
Body temperature measurement error: no greater than ±0.1℃
Resolution: 0.1℃
Accuracy: ± 0.2 ℃ (including the error of the sensor)
Standard configuration: body surface permanent body temperature probe
Select configuration: esophageal body temperature probe, rectal body temperature probe
Alarm value: upper and lower limits can be set, automatic memory
Alarm: alarm settings can be set for all monitoring parameters, and has an alarm device that emits sound and light, and can cancel the alarm
Respiration:
Measurement method: thoracic impedance method
Respiratory rate measurement range and accuracy
Measurement range: Equidae: 0~ 120rpm.
Canine/Feline: 0~ 150rpm.
Measurement accuracy: 10~150 rpm ±2 rpm or ±2%, whichever is greater.0~9 rpm is not defined.
Respiration rate measurement resolution
Resolution: 1 rpm
Asphyxia alarm delay time
Can be set as: 20s, 25s, 30s, 35s, 40s, 45s, 50s, 55s, 60s
Respiration rate alarm limit range
Alarm limit can be set from 2 to 150rpm